5.5 Common parameter setting mode SET 4 (1)
SV limiter upper limit (*2) (*3)
Thermocouple/RTD input (SLL + 5.0) to SV setting range upper limit (C)
(SLL + 5) to SV setting range upper limit (C)
Current/voltage input (SLL + 50) to SV setting range upper limit (digit)
SV limiter lower limit (*2) (*3)
Thermocouple/RTD input SV setting range lower limit to (SLH - 5.0) (C)
SV setting range lower limit to (SLH - 5) (C)
Current/voltage input (SLH - 50) to SV setting range lower limit (digit)
Secondary---onoff control
Secondary---onoff control
Forward/reverse operation setting
Primary control operating amount
Primary/secondary auto-tuning
Thermocouple/RTD input 0.0 to 999.9 (°C) 0 to 999 (°C)
Voltage/current input 0 to 9999 (digit)
AT startup screen for PID No. 1 (low
temperature)
Startup starts/stops by setting a SV and using the RUN/STOP key.
Characters and PV are alternately displayed in the PV digit during AT.
The SV range is SLL to PM1.
AT startup screen for PID No. 2
(intermediate temperature)
Startup starts/stops by setting a SV and using the RUN/STOP key.
Characters and PV are alternately displayed in the PV digit during AT.
The SV range is PM1 to PM2.
AT startup screen for PID No. 3 (high
temperature)
Startup starts/stops by setting a SV and using the RUN/STOP key.
Characters and PV are alternately displayed in the PV digit during AT.
The SV range is PM2 to SLH.
AT startup screen for PID No. 1~3
Use the RUN/STOP key for start and stop.
During the auto tuning, Character//PV is alternately displayed at PV
display, and No. 1 – 3/SV are alternately displayed at SV display.
Proportional band setting for PID No. 1 (low temperature)
Integral time setting for PID No. 1 (low temperature)
Derivative time setting for PID No. 1 (low temperature)
Intermediate point 1 setting for the
PID range
Thermocouple/RTD input SLL to SLH- 5.0 (C) SLL to SLH - 5 (C)
Current/voltage input SLL to SLH - 50 (digit)
Proportional band setting for PID No. 2 (intermediate
temperature)
Integral time setting for PID No. 2 (intermediate temperature)
Derivative time setting for PID No. 2 (intermediate
temperature)
Intermediate point 2 setting for the PID range
Proportional band setting for PID No. 3 (high temperature)
Integral time setting for PID No. 3 (high temperature)
Derivative time setting for PID No. 3 (high temperature)
Primary control proportional cycle
0.0 to 110.0 (%) Function turned off at 110.0 (%) setting
Primary control loop abnormalityPV
variation setting
Thermocouple/RTD input 0.0 to 999.9 (C) or 0 to 999 (C)
Current/voltage input 0 to 9999 (digit)
Primary control loop abnormality time
setting
Primary control off-point position
selection setting
Primary control sensitivity control
Thermocouple/RTD input 0.0 to 999.9 (C) 0 to 999 (C)
Current/voltage input 0 to 9999 (digit)
Primary control off-point position
Thermocouple/RTD input -999.9 to 999.9 (C) -999 to 999 (C)
Current/voltage input -9999 to 9999 (digit)