Identifier
Relative
address
Absolute
address
Character
Name R/W
Description
□MD
0028h
40041
C
o
ntrol mode
setting
R/W
R/W the control mode setting
Control execution: 00000
Manual control: 00001
Control stop: 00002
Auto
-
tuning in progress:
00003
CNT
002Ah
40043
S
election of
control type
setting
R/W
R/W the control type se
tting
DIR
002Ch
40045
Change of normal or reverse
R/W
R/W the forward/reverse operation
switchover setting
MV1
002Eh
40047
Manipulated value
for o
utput 1
R/W
R/W the output 1 operation amount
TUN
0030h
40049
Set
for PID
tuning type
R/W
R
/W the tuning type setting
ATG
0032h
40051
AT
coefficient setting
R/W
R/W the AT factor
ATC
0034h
40053
AT sensitivity
setting
R/W
R/W the AT sensitivity
□P1
0036h
40055
P
roportional band
s
et
ting
for
output
1
R/W
R/W the output 1 proporti
onal band setting
□I1
0038h
40057
I
ntegral time
setting
R/W
R/W the integral time setting
□D1
003Ah
40059
D
erivative time
setting
R/W
R/W the derivative time setting
□T1
003Ch
40061
P
roportional
cycle setting
F
or
output 1
R/W
R/W the out
put 1 proportional frequency
setting
ARW
003Eh
40063
ARW(
Anti
-
reset windup
) setting
R/W
R/W the anti
-
reset windup
MH1
0040h
40065
High limit setting of manipulated
value for output 1
R/W
R/W the amount
-
of
-
operation limiter upper
limit setting
ML1
0042h
40067
Low limit setting of manipulated
value for output 1
R/W
R/W the amount
-
of
-
operation limiter lower
limit setting
□C1
0044h
40069
C
ontrol sensitivity
s
et
ting
for
output 1
R/W
R/W the output 1 control sensitivity setting
CP1
0046h
40071
OFF
position
setting for
output 1
R/W
R/W the output 1 off
-
point position setting
MV2
0048h
40073
Manipulated value for o
utput
2
R/W
R/W the output 2 operation amount
□P2
004Ah
40075
P
roportional band
s
et
ting
for
output
2
R/W
R/W t
he output 2 proportional band setting
□T2
004Ch
40077
P
roportional
cycle setting for
output
2
R/W
R/W the output 2 proportional frequency
setting
MH2
004Eh
40079
High limit setting of manipulated
value for output 2
R/W
R/W the amount
-
of
-
operati
on limiter upper
limit setting
ML2
0050h
40081
Low limit setting of manipulated
value for output 2
R/W
R/W the amount
-
of
-
operation limiter lower
limit setting
□C2
0052h
40083
C
ontrol sensitivity
s
et
ting
for
output
2
R/W
R/W the output 2 contro
l sensitivity setting
CP2
0054h
40085
OFF
position
setting
for
output
2
R/W
R/W the output 2 off
-
point position setting
PBB
0056h
40087
Manual reset
setting
R/W
R/W the manual reset
□DB
0058h
40089
D
ead band
setting
R/W
R/W the dead band
setting
RP1
005Ah
40091
SV
R
amp
variation setting
R/W
R/W the SV lamp time setting
RP2
005Ch
40093
SV
2
R
amp
variation setting
R/W
R/W the SV2 lamp time setting
E1F
005Eh
40095
F
unction
s
et
ting for EV1
R/W
R/W the PV event output 1 functi
on setting
E1H
0060h
40097
High limit setting for EV1
R/W
R/W the event output 1 upper limit setting
E1L
0062h
40099
Low limit setting for EV1
R/W
R/W the event output 1 lower limit setting
E1C
0064h
40101
Control
sensitivity
setting
for EV1
R/W
R/W the event output 1 sensitivity setting
E1T
0066h
40103
D
elay time
setting for EV1
R/W
R/W the event output 1 delay timer setting
Vista de página 37