7.9.8 Setting and reading data collectively
1) Composition of a read request message
a) All channels
S
T
X
A
R
E
T
X
B
C
C
―⑤―
Start code
Unit number
Channel
Contents of the
request: read
Identifier
End code
BCC data
2) Composition of a write request message
a) All channels
S
T
X
A
W
E
T
X
B
C
C
―⑤― ―――⑥―――
Start code
Unit number
Channel
Co
ntents of the
request: write
Identifier
Numerical data
End code
BCC data
3) Composition of a store request message
a) All channels
S
T
X
A
W
S
T
R
E
T
X
B
C
C
―⑤―
Start code
Unit number
Channel
Contents of the
request: write
Identifier
End code
BCC data